Gear & Supplies
What Size Generator Do I Need? A Plain Wattage Guide
General information only, not professional advice. In an emergency, call 911 and follow local officials. How we use sources
In this guide
You size a generator by adding up what you need to run, not by the square footage of your house. Two numbers come out of that: the total running watts of everything you want on at once, and the extra burst needed when the single biggest motor, such as a sump pump or a refrigerator compressor, starts up. Shop for a generator that covers both.
This guide covers how to find your numbers, what common loads draw, a worked example, and where portable sizing stops. Nothing here comes from testing a generator. The method and the safety text come from the U.S. Department of Energy, the Consumer Product Safety Commission (CPSC), the CDC, OSHA and Ready.gov, and the appliance figures come from makers’ published charts.
The two numbers you need
Running watts are what a device draws while it is operating steadily. A generator has a running (or rated) watts figure, and the sum of your devices has to stay under it.
Starting watts are the short burst a motor pulls when it first turns on. Refrigerators, freezers, sump pumps, furnace fans and air conditioners all have a higher starting figure than running figure on Champion Power Equipment’s published chart. The same chart marks lights, a router and a TV as needing no extra starting watts.
Greengear, a generator maker, sizes for one startup at a time and explains why in its sizing FAQ:
“In most cases, only one item will start or cycle at the same time.”
Source: Greengear, Generator Sizing Charts (greengearglobal.com), accessed November 2026. This is the maker’s published chart and FAQ, not a federal source.
Following that method, you add up all the running watts, then add only the one largest startup burst, rather than every startup burst together.
Check one thing before you start. Maker charts do not all list starting watts the same way. Champion’s chart lists a starting figure for each appliance that is higher than its running figure, which reads as the total needed at the moment of startup. Greengear’s chart lists “Additional Starting Watts,” meaning the amount above the running figure. If you mix the two, you will either count the running watts twice or leave out the burst. Check the column heading.
Find your own numbers
Charts give you a ballpark. The Department of Energy describes three ways to find the real figure: read the label, multiply amps by volts, or use a plug-in meter.
“The wattage of most appliances is usually stamped on the bottom or back of the appliance, or on its nameplate. The wattage listed is the maximum power drawn by the appliance.”
“If the wattage is not listed on the appliance, you can still estimate it by finding the electrical current draw (in amperes) and multiplying that by the voltage used by the appliance. Most appliances in the United States use 120 volts. Larger appliances, such as clothes dryers and electric cooktops, use 240 volts.”
“To find out how many watts of electricity a device is using, just plug the monitor into the electrical outlet the device uses, and then plug the device into the monitor. It will display how many watts the device uses.”
Source: U.S. Department of Energy, Estimating Appliance and Home Electronic Energy Use (energy.gov), accessed November 2026.
Notice the word maximum. A nameplate figure is the most the appliance will draw, so a total built from nameplates tends to come out high rather than low. The same page says its sample wattages vary with product age and features, and the same goes for every chart number here. Your label or your meter wins.
The 120 volt versus 240 volt split matters for sizing. Most things in a home plug into an ordinary 120 volt outlet. DOE names clothes dryers and electric cooktops as 240 volt appliances. Honda’s published wattage guide also marks the electric clothes dryer, electric range and hot water heater as needing 240 volts, and it puts the same mark on its furnace fan and sump pump rows, so read the voltage on your own unit’s label before you plan around it.
What common outage loads draw
Here are the figures from Champion Power Equipment’s published wattage chart, which lists a range for each appliance because models differ. Where the starting column says “none extra,” the chart marks the appliance as needing no extra starting watts, so you size it on running watts only.
| Load | Running watts | Starting watts |
|---|---|---|
| Refrigerator | 150 to 400 | 800 to 1,200 |
| Freezer | 100 to 500 | 500 to 1,000 |
| Sump pump (1/3 HP) | 500 to 800 | 1,000 to 1,600 |
| Furnace fan (1/2 HP) | 300 to 800 | 800 to 1,600 |
| Well pump (1/2 HP) | 750 to 1,000 | 1,500 to 2,000 |
| Window AC (5,000 BTU) | 450 to 600 | 900 to 1,200 |
| Window AC (10,000 BTU) | 900 to 1,200 | 1,800 to 2,400 |
| Central AC (3 ton) | 3,000 to 3,500 | 5,000 to 6,000 |
| Microwave | 600 to 1,200 | none extra |
| Space heater | 750 to 1,500 | none extra |
| TV (32 to 55 inch) | 80 to 400 | none extra |
| LED bulb (each) | 8 to 15 | none extra |
| Phone or laptop charger | 20 to 100 | none extra |
| CPAP without heat | 30 to 60 | none extra |
| Internet router or modem | 10 to 20 | none extra |
Source: Champion Power Equipment, Generator Wattage Chart: Common Appliances & Tools (championpowerequipment.com), maker’s published chart, accessed November 2026.
The same chart lists an electric water heater at 3,000 to 4,500 running watts and an electric dryer at 4,000 to 6,000.
Makers’ figures do not agree. Honda’s guide lists an Energy Star refrigerator or freezer at 132 to 192 running watts and 1,200 starting. Greengear’s chart lists a refrigerator or freezer at 700 running watts plus 220 additional starting watts. Champion’s range runs from 150 to 400. Read your own label instead of trusting any one chart.
A worked example, using example numbers
Everything in this section is an example. The numbers are not a recommendation, and they are not your house. They are built from the high end of Champion’s ranges above so that you can see the arithmetic. Swap in your own figures.
The example list is a refrigerator, a freezer, a furnace fan, a sump pump, six LED bulbs, a laptop charger, a router and a TV.
| Example load | Running watts | Starting watts | Extra needed to start |
|---|---|---|---|
| Refrigerator | 400 | 1,200 | 800 |
| Freezer | 500 | 1,000 | 500 |
| Furnace fan | 800 | 1,600 | 800 |
| Sump pump | 800 | 1,600 | 800 |
| Six LED bulbs (15 each) | 90 | none extra | 0 |
| Laptop charger | 100 | none extra | 0 |
| Router | 20 | none extra | 0 |
| TV | 400 | none extra | 0 |
| Example total | 3,110 | Largest single extra: 800 |
The steps:
- Add the running watts: 400 + 500 + 800 + 800 + 90 + 100 + 20 + 400 = 3,110.
- Work out the extra each motor needs at startup, which is its starting watts minus its running watts. Refrigerator: 1,200 minus 400 is 800. Freezer: 1,000 minus 500 is 500. Furnace fan: 1,600 minus 800 is 800. Sump pump: 1,600 minus 800 is 800.
- Take the single largest extra, which is 800, and add it to the running total: 3,110 + 800 = 3,910.
In this example, the generator needs at least 3,110 running watts and at least 3,910 starting watts.
Now suppose the same example house also wants a 10,000 BTU window air conditioner, using the high end of Champion’s range: 1,200 running watts and 2,400 starting, so 1,200 extra at startup.
| Example, with window AC added | Running watts | Starting watts needed |
|---|---|---|
| Earlier list | 3,110 | 3,910 |
| Window AC added | 3,110 + 1,200 = 4,310 | 4,310 + 1,200 = 5,510 |
The air conditioner now has the largest startup extra (1,200, more than the earlier 800), so that is the one added on top. In this example, one appliance moved the starting requirement from 3,910 watts to 5,510, which is why it pays to build the list before you shop.
Cut the list before you buy bigger
Before you buy a bigger generator, check whether a shorter list does the job. Honda’s wattage guide opens its home table with this tip, and points readers to its power management section on using a smaller generator to power more:
“Don’t just add up the total wattage for everything you want to power.”
Source: Honda Power Equipment, Generator Wattage Estimation Guide (honda.com), maker’s published guide, accessed November 2026. This is a maker’s page, not a federal source.
The practical version is to ask which loads truly have to run at the same moment. In the example above, a household that needs the furnace fan in a winter outage and the window AC in a summer one may not need both on the same day. Taking the furnace fan off the summer list brings that example from 4,310 to 3,510 running watts. The AC is still the biggest start, so the starting figure drops from 5,510 to 4,710. A lower total also leaves more room under the generator’s rating, which matters because OSHA warns against overloading (quoted below).
Some loads are too big to fit by rotating. On Champion’s chart, central air (3 ton) runs at 3,000 to 3,500 watts, an electric water heater at 3,000 to 4,500, and an electric dryer at 4,000 to 6,000, each on its own. EcoFlow, which makes power stations and publishes its own sizing guide, offers three rough bands, and they are one maker’s view and not a rule. Its bare essentials band is 2,000 to 4,500 watts. A band that adds a well pump and a furnace fan is 5,000 to 8,500 watts. A whole-house band, which is where it puts central air, an electric water heater, an electric stove and a dryer, is 12,000 to 22,000 watts. The same post says the most important factor is not square footage but the specific appliances and systems you plan to run, and that whole-house power with central air calls for a standby generator and a professional load calculation.
If your list lands in that whole-house range, the next conversation is with a licensed electrician, not a store shelf. For portable units that fit the smaller bands, our roundup of portable generators for home power outages is the next place to look.
Safety limits that change your plan
Two federal safety points affect sizing directly, because they decide how you connect the generator and where it sits.
How you connect it. The CPSC says:
“NEVER try to power the house wiring by plugging the generator into a wall outlet, a practice known as “backfeeding.” This is extremely dangerous and presents an electrocution risk to utility workers and neighbors served by the same utility transformer. It also bypasses some of the built-in household circuit protection devices.”
Source: CPSC, Portable Generator Hazards (cpsc.gov), accessed November 2026.
OSHA explains the one allowed exception, and it is not a do-it-yourself job:
“Never attach a generator directly to the electrical system of a structure (home, office, trailer, etc.) unless a qualified electrician has properly installed the generator with a transfer switch.”
Source: OSHA, Using Portable Generators Safely (osha.gov), accessed November 2026.
Without a transfer switch, then, the generator powers things through cords plugged into it. That brings in the cord rating, which is part of sizing too. The same CPSC alert says:
“Connect appliances to the generator using heavy-duty extension cords that are specifically designed for outdoor use. Make sure the wattage rating for each cord exceeds the total wattage of all appliances connected to it.”
Source: CPSC, Portable Generator Hazards (cpsc.gov), accessed November 2026.
OSHA adds a warning that ties back to the list you just built:
“Do not overload a generator; this can lead to overheating which can create a fire hazard.”
Source: OSHA, Using Portable Generators Safely (osha.gov), accessed November 2026.
The federal pages quoted here give no safe loading percentage, so this article does not give one either. Ready.gov’s power outage page says:
“Follow manufacturer’s instructions carefully.”
Source: Ready.gov, Power Outages (ready.gov), accessed November 2026.
Where it sits. The generator also has to be outside. The CDC says:
“Never use a generator, pressure washer, or any gasoline-powered engine inside your home, basement, or garage or less than 20 feet from any window, door, or vent.”
“When using a generator, use a battery-powered or battery backup CO detector in your home.”
Source: CDC, What to Do to Protect Yourself During a Power Outage (cdc.gov), accessed November 2026.
We keep a list of carbon monoxide detectors, and there is a separate page on how far a generator should sit from the house. When you shop, the CPSC also says:
“DO ask retailers for a portable generator with a safety feature to shut off automatically when high CO concentrations are present.”
Source: CPSC, What to Know About Generators and Carbon Monoxide (CO) (cpsc.gov), accessed November 2026.
Follow the instructions of your local emergency officials, and call 911 in an emergency. When in doubt, don’t. If you are unsure about a connection or a load, ask a licensed electrician or the maker before you run anything. Our page on what to do when the power goes out covers the broader outage steps.
Generator or power station?
If your list is short, a portable power station may cover it. A router, phone and laptop chargers, and a CPAP without heat sit at the low end of Champion’s chart, in the tens of watts each. Motor loads and long lists are where you are more likely to need a generator. Either way, check the unit’s rated output against your list the same way you did above. Our guide to portable power stations covers the small-load side, and the generator or portable power station section of our gear list shows both options side by side.
Frequently asked questions
What size generator do I need for a 2,000 square foot house? There is no single answer, because the loads draw power, not the floor area. Build your list, add the running watts, and add the largest startup extra.
Can a small generator run a whole house? Not all of it at once. A small unit can cover a short list if you rotate loads and leave off the big items such as an electric water heater, dryer or central air. Wiring any generator to the house takes a qualified electrician and a transfer switch, per OSHA. Otherwise it powers individual items through properly rated cords.
How many watts does a refrigerator use? It depends on the model, and makers’ charts disagree. Our page on how many watts a refrigerator uses goes through reading your own fridge’s numbers.
Can I plug a generator into a wall outlet? No. The CPSC calls this backfeeding and says it is extremely dangerous. If you want the generator connected to your house wiring, OSHA says that takes a transfer switch installed by a qualified electrician.
How many watts does a CPAP machine need? Champion’s chart lists 30 to 60 watts without heat and 60 to 120 watts with a heated humidifier. Check your own machine’s label, and confirm anything medical with your provider.
Keep the list somewhere you can find it
The list you built here is worth writing down once, on paper, so it is at hand the next time the lights go out. The Power Outage page of our family emergency binder holds the first steps, the utility’s outage number and the generator carbon monoxide rules, and your load list fits behind it.